That’s some soupy fine aggregate concrete, thin shelled precast piece by looking at the vertical clearance, I wonder if the “rock” segregated out on those vertical walls.
To everyone who are barking in the comments section: a concrete is said to be SCC if it fulfills 1. Filling ability 2.passing ability 3. Resistance to segregation. We hv different tests to perform n chck the properties..this test falls in the category of filling ability, known as the slump flow test. In which we measure the diameter of the spread. The range is 500mm to 800mm..but for reinforced sections it should satisfy 700mm-800mm(SF3) category. And for your information, the orientation of the slump cone has little or nothing to do with in SCC. It's just to fill the concrete easily in the cone. Thats it
That wasn't a slump test pouring that way will give you segregation and that much water in the mx will make weak concrete ,,,all in all a crappy concrete pour !
Phil MacGregor that’s called a spread test. Getting the concrete that wet was 100% chemicals. You can tell by the lack of segregation. W/c is probably in the .40-.45 range. I’m sure its a good strong mix.
We did this scc on our final year project. The slump indicates the horizontal flow ability of scc..i,e without any obstruction to its flow in any reinforcement. As per EFNORC guidelines the slump flow should be lies in between 650 MM TO 800MM then only it becomes a scc mix. After this test V-funnel and L-box test was also conducted to know it's filling ability in any vertical form work and passing ability on horizontal surface.
self compacting concrete
What did they measure
The slump cone is wrong side up!
It’s not slamming ,it’s slump testing.
Good lord why even slump test that straight water would not have been any different
What is it ?
That’s some soupy fine aggregate concrete, thin shelled precast piece by looking at the vertical clearance, I wonder if the “rock” segregated out on those vertical walls.
Srpski hi tech
queria ver a peça pronta
Dobro!
Какую марку бетона используйте?
o nice.....may I ask for the material properties and the concrete job mix 👍
Hallo! Was von Firma ist das?
In 50+ years, I’ve NEVER seen a slump test performed like that!!!
I thought I was in a different world.
This guy is holding the cone upside down... for a proper slump test the cone sits on the larger diameter side
What the fuck did I just watch?
To everyone who are barking in the comments section: a concrete is said to be SCC if it fulfills 1. Filling ability 2.passing ability 3. Resistance to segregation. We hv different tests to perform n chck the properties..this test falls in the category of filling ability, known as the slump flow test. In which we measure the diameter of the spread. The range is 500mm to 800mm..but for reinforced sections it should satisfy 700mm-800mm(SF3) category. And for your information, the orientation of the slump cone has little or nothing to do with in SCC. It's just to fill the concrete easily in the cone. Thats it
What is this called and used for?
Oh the suspense.... Has cost you a thumbs down...down....down
Wow. These acrylic pour videos are getting serious.
😂🤣
That wasn't a slump test pouring that way will give you segregation and that much water in the mx will make weak concrete ,,,all in all a crappy concrete pour !
Phil MacGregor that’s called a spread test. Getting the concrete that wet was 100% chemicals. You can tell by the lack of segregation. W/c is probably in the .40-.45 range. I’m sure its a good strong mix.
Mudaki
??????
Lol was für noobs
Why did I think this would be good !
Estais tontos..tantas personas y se escapa hormigon.....mediotontos
How much slump do you want?? All of it
100% slump for SCC .we measure the horizontal spread n not the vertical distance as in case of vibrated concrete.
Up side down
Der hält den Trichter falsch herum da wird beschissen 😃😃😂😂
Hahaha koja technology
El cono de Abraham se usa al reves!
difficulty full hook fzqkoh professional unexpected program term broken coach three.
Yes, precisely
Откуда берутся такие тупорылые
Конус с другой стороны наполняют.😆
у них всё с другой стороны...еврожопа...
Giggling tuvjvfhobckgflvlti kjkkkkkkkkkkjogxod jc
и после этого они пытаются научить нас строить????? ХА ХА ХА
Вас учить , что фуй тупить.
Ja ja ja , menuda mierda de hormigón que lleva agua para ahogar los peces
Die brauchten die Rüttelplatte nicht mal bewegen ,schon lief die Brühe, schätze B20 Festigkeit
El cono de Abrams
mas que lambança, porqueira
ruclips.net/video/uccwVWRhDkk/видео.html
Maximum size aggregate?
10 mm.
@@user-th6zc3fs3m ok, 10mm coarse aggregate The smaller the aggregate used, the more cement there is or is there another solution?
Wah ga bisa tahu job mix formulanya ya
Сука бетон проверяют на текучесть по американской технологии а кувалдой долбит по таджикской пиздец полный...
Akışkan beton
Шо это за хуйня?
We did this scc on our final year project. The slump indicates the horizontal flow ability of scc..i,e without any obstruction to its flow in any reinforcement. As per EFNORC guidelines the slump flow should be lies in between 650 MM TO 800MM then only it becomes a scc mix. After this test V-funnel and L-box test was also conducted to know it's filling ability in any vertical form work and passing ability on horizontal surface.
Did they know that it was upside down lol
German equaliser
Лаборант мудила конус в верх ногами поставил ..
Bosanci i Slavonci a ko bi drugi
shit